Add to Cart
65W Output Power Smart Automatic 12V 24V 5A 10A 20A DC AGM Sealed Lead Acid Battery Charger for Cars
Smart automatic 12v 24v 5a 10a 20a dc AGM sealed lead acid battery charger battery car charger
Input Voltage | AC 130V-250V |
Frequency | 50Hz/ 60Hz |
Output Voltage | DC 12V/ 24V adjustable |
Temperature | -20°c to +40°c |
Battery type | GEL+AGM |
Repair mode | One -button repair mode |
Full load conversion efficiency | 93% |
Automatic intelligent | 12v/24v battery |
Current | 5A 10A 20A |
Cooling | Fan cooling |
Shenzhen Shengshi Tianhe technology Co., LTD. was founded in 2002 and factory has over 8000 square meters. At the end of 2017, the company have 500 employees, including technical research and development and management staff more than 65 peoples. SZSSTH are hi-tech enterprise which is engaged in R&D, production, sales and service of power inverter, solar inverter, solar panel, solar charge controller, solar power bank & power station, universal laptop adapter, car jump starter , switching power and so on. We obtained the CE ROHS FCC LVD TUV, UL, KC, SAA,SGS,UKCA, REACH, PAHS ,BSCI, NF GS and others certificates for our product. Our products are exported to many countries and regions such as Eurasian, North and South America, Middle East and Africa.
Packing: Gift box
PCS/CTN :2pcs
Product Dimension :235X215X165mm
Unit Weight: 6.5kg
Net weight (N.W): 13kg
Gross weight (G.W): 16kg
Q1.The electric appliance doesn't work and the indicator light isn't on.
Reason:
1. Faulty battery.
2. Wrong connection of positive pole and negative pole.
3. Loose connection of the cables.
Answer:
1. Check the battery, and change it if needed.
2. Check the connection of battery. The inverter might be damaged and should be changed or sent to be repaired.
3. Check the cables and connection points, and tighten the terminals.
Q2. The electric appliance doesn't work and the RED indicator light is on.
Reason:
1. The rated power of electric appliance exceeds the nominal power of inverter which leads to over load shut down.
2. The rated power of electric appliance is less than the nominal power of the inverter but its peak power is too high which leads to over load shutdown.
3. The electricity in battery runs out (the inverter alarms)
4. Poor ventilation causes over heat shutdown
5. Input voltage is too high.
Answer:
1. Please use the electric appliance which power is less than the nominal power of inverter.
2. The peak power of electric appliance is no more than that of power inverter, or the same power.
3. Charge the battery or change it.
4. Turn off the inverter for 15 minutes, remove the items near fan and those around the inverter,and put the inverter in a shady and cool place
5. Turn off the inverter and test the output voltage of battery.
Q3. The output voltage of power inverter tested is too low.
Reason: Generally the numerical reading range of voltmeter for testing use is too small.
Answer: If you test the output voltage of modified sine wave inverters, please use "true RMS?
Muti-meter" to obtain the accurate data.
Q4. Only small power load can be driven.
Reason: When the current goes through the cables, the voltage declines.
Answer: Shorten the length and use thicker cables.
Q5. The hours of use are too short.
Reason:
1. The electricity consumption of the electric appliance is larger than rated load of power inverter.
2. The battery is faulty or damaged
3. The battery is not well charged
4. The current declines when through cables
Answers:
1. Use larger capacity battery.
2. Change battery.
3. If the charger can't charge the battery fully, it needs to change a better intelligent charger.
4. Shorten the length of the cables and use the thicker cables.